Replacing the fuse after melt-through.
Replacing the fuse is possible without opening the module! (if
the module has been opened the guarantee no longer applies).
Remove the film above the fuse and then pull the fuse out of the
module with pointed pliers.
Replace the fuse with a fuse of one of the following types (with
the application of other types the guarantee no longer applies):
Supplier dimmer fuse Description Order number supplier
Littelfuse LT-5 ALg 0663.01.6
Bussman ETF Radial Lead Micro Fuse BK ETF1.6
ELU Sub miniature fuse links 166050-1,6AT
Wickmann Subminiatur fuse No 372.TR5 372-1160-041
Bel fuse Time Lag Radial Lead Micro Fuse MTR1,6 short leads
NEVER CONNECT A WOUND VOLTAGE TRANSFORMER TO THE
LWM1P WHILE THE VOLTAGE IS SWITCHED ON. T
HE FUSE CAN
MELT AS A RESULT.
LOW VOLTAGE HALOGEN LIGHTING
The LWM1P can only be used in combination with the electronic
transformer suitable for leading-edge phase dimmers. The
LWM1P cannot be coupled to transformers suitable for trailing-
edge phase dimmers. Coupling it to such a transformer will cause
a humming sound and damage the LWM1P. The right to
guarantee will also expire as a result.