FREQENTLY ASKED QUESTIONS
What is the reason for modules to switch on/o
ff spon-
taneously?
It is possible that a Haibrain X-10 System is installed at one
of your neighbours using the same House Code. To solve
this problem try to change the House Code of your system.
Must the FD10 be placed before or after the earth
switch?
In general the FD 10 can be connected best after the three
phase main switch of a 400 V group (for instance the
cooker group). When earth switches are used the FD10
must be installed before these switches. By doing so unde-
sired switching off of these switches is prevented.
How many FD10 units do I need in my house for phase
coupling?
For a 1-phase system: 0 FD10 modules are necessary.
For a 2-phase system: 1 FD10 modules are necessary.
For a 3-phase system: 3 FD10 modules are necessary or a
CAT3000 (product info CAT3000). When using MicroMod-
ules (product info MicroModules) always use the CAT3000.
Can I also use MicroModules if I have FD10 modules?
Yes, the only thing that will not work, is the transmission
function (2-way communication, status indicator) of the
AWM2, TMA4, TMD4 and the LWM1. The AW12 and LW12
have no 2-way communication and will work normally. If
you want to use 2-way communication, you need to use the
CAT3000 for coupling.