1
The alarm warning does not appear on the display when a panic alarm is triggered.
If the Power LED is…
a
It means…
Off Both AC and Battery power are disconnected.
On System Power is OK.
Flashing (slow)
Backup battery low or low battery from transmitters.
Flashing (fast)
AC loss.
Table 3.2: Power supply status Indicators
Arm Status Display
The Arm Status Display contains the current status of the display and possible error
messages in the system. You can choose whether you want to see this information
continuously or just for two minutes after switching the system on or off. By default this is set
for two minutes after switching the system on or off, so when someone is breaking into your
house he cannot see whether the ProGuard800 alarm system is switched on or off, and so the
system is able to sound a “silent alarm”.
To set the Arm Status Display to display always:
1. Log in to the programming menu by pressing 9 followed by 1111 (the display now
show
s: MAIN MENU 1.STOP COMM.).
2. Press 94061 (the display now shows: 6.DISPLAY 1. ARM STATUS
).
3. P
ress 9
4. P
ress (the display now shows: 1. ARM STATUS DISPLAY ALWAYS
).
5. P
ress 9
6.
You can leave the programming menu by pushing 8
5 times.
RP P
ass code
The RP (remote programming) pass code is a six character code which allows remote
programming. When a RP connection is established, the programmed RP pass code on the PC
should be the same as the RP pass code of the central unit. The default RP pass code is 123456.
We advice you to change this code in your own unique code immediately.
To change the RP Pass code:
1.
Log in to the programming menu by pressing 9 followed by 1111 (the display
now
show
s: MAIN MENU 1.STOP COMM.).
2.
Enter 9522 (the display now shows: 2.RP PASSCODE 123456
).
3.
Enter six
characters.
4. Push
9 w
hen you are done changin
g.
You have now configured the
basic settings of your ProGuard800 set. We refer to your
installation manual for further configuration possibilities of your ProGuard800 and to your user
manual for the daily use of your ProGuard800.