Setting date and time
1. Press 9 followed by 1111.
2. Press 7 99.
3. Now enter the correct time followed by 9.
4. Now enter the correct date followed by 9.
5. Press 8 3 times to leave the installation menu.
Switching off the siren
1. Press 9 followed by 1111.
2. Now enter 9155 (the display shows: 5.WIRED SIREN ENABLED).
3. Now press (the display shows: 5.WIRED SIREN DISABLED).
4. Press 9 for confirmation.
5. Press 8 4 times to leave the installation menu.
The internal siren is still disconnected. You can now reconnect the plug of the internal siren
and attach the front of the central unit to the back using the hooks and then close the central
unit.
Registering of sensors
The ProGuard800 has 33 protected zones. Zones 1-32 are meant for wireless sensors.
Per zone 1 sensor can be registered. The Haibrain ProGuard800 supports various
wireless components like PIR sensors, magnet contacts and smoke detectors. Each zone
can
be set to be a normal zone, or a zone with an entrance delay, or else. These zones are
factory set for various sensors by the manufacturer to make registering them very easy
for you. For an overview of the factory settings see the end of this installation manual. To
indicate that the ProGuard800 is still activated when you enter your house, it is
recommended to equip the entrance door with a Door/Window sensor with an
entrance delay. When entering the ProGuard800 indicates with sounds that the alarm is
still switched on.
You can now choose to install a Door/Window sensor with or without an entrance delay.
Registering a Door/Window sensor with entrance delay
1
Zones 1 and 2 are factory set for using a Door/Window sensor (DS831) with
entrance delay.
Programming
1. Go to the programming menu by pressing 9 followed by 1111.
(the display now shows: MAIN MENU 1.STOP COMM.).
2. Press 9 (the display now shows: 9.PROGRAMMING 1.DEVICES).
3. Press 9(the display now shows: 1.DEVICES 1.ZONES).
4. Press 9( the display now shows:1.ZONES ZONE #1).
5. Press 9( the display now shows:1.Z1 REGISTER TRANSMIT 1).
The ProGuard800 will now wait till the DS831 sends a signal.
6. Get the Door/Window sensor (DS831) from the box and open the housing by
sticking a screwdriver between the front and the back of the contact (near the
Haibrain
logo at the bottom) and turning it.
7. Remove the red plate between the battery and the battery contact.
8. The ProGuard800 now makes a short beeping sound and the display shows: 1.Z1
REGISTER TRANSMIT 2. Wait for five seconds or push the sabotage contact and
you will again hear a short beep (the display now shows: 1.Z1 REGISTER SAVE?).