  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
9. Press 9 to confirm. Now you will hear a long beep.
10. If you not wish to register any other sensors, press
8
5 times to leave the
programming menu.
11.
The DS831 is now registered and is default set with an entrance delay
of 30 sec.
12.
Do not close the housing yet, hereafter in this manual you can learn how to place
the sensor.
Registering of a Door/Window sensor without entrance
delay
1
Zones 3 to 9 inclusive are factory set for the use of a DS831 without entrance
delay.
1. Follow the same routine as when reporting a Door/Window sensor WITH entrance
delay
till you reached step four (the display now shows: 1.ZONES ZONE #1
).
2. Choo
se with till the display says: 1.ZONES ZONE #3.
3. Now continue with step five (above).
Registering a moveme
nt detector
Opening MS84
5
1.
Open the housing of the Motion sensor(MS845) by
removing the front. This is done easiest by sticking a
screwdriver in the unlock slot (at the bottom of
the
detector, between front- an
d backside of
the
sensor). Now
move the screwdriver upw
ard.
2.
Supply the Motion sensor with power by removing the red plate which separates
the battery from the battery
contacts.
1
Due to
possible voltage delay in lithium batteries that have been stored, the
batteries might seem empty at first. When this happens, leave the sensor for
a few minutes till the voltage level is stabilised.
Programming
If the ProGuard800 is still in programming mode after registering the door/window sensor,
then push
8
once (the display now shows: 1.ZONES ZONE #x). Follow the instructions from
step five (below).
1
Zones 11 to 19 inclusive are factory set for using a MS845
If the ProGuard800 is not in programming mode, act as follows:
1.
Log in to the programming menu by pressing 9, followed by 1111 (the display now
shows: MAIN MENU 1.STOP COMM.
).
2.
Press 9 (the display now shows: 9.PROGRAMMING 1.DEVICES).
3. Press
9 (the dis
play now shows: 1.DEVICES 1.ZONES
).
4. Press
9 (the display now shows: 1.ZONES ZONE #1).
5. Choose with till the display shows: 1.ZONES ZONE #11
.
6. Press
9 (the dis
play now shows: 1.Z11 REGISTER TRANSMIT 1
).
ProGuard800